LE910Cx Hardware Design Guide
1VV0301298 Rev.40 Page 85 of 149 2023-03-16
Not Subject to NDA
Parameter Comments
Min Typ Max Unit
t(suauxdin)
AUX_PCM_DIN setup time to
AUX_PCM_CLK falling
70 - - ns
t(hauxdin)
AUX_ PCM_DIN hold time after
AUX_PCM_CLK falling
20 - - ns
t(pauxdout)
Delay from AUX_PCM_CLK to
AUX_PCM_DOUT valid
- - 50 ns
Table 35: AUX_PCM_CODEC Timing Parameters
8.6.1.3. I2S Digital Audio Diagram