Do you have a question about the TESTING Vicat and is the answer not in the manual?
Identifies the device using its nameplate information.
Explains the intended use of the apparatus for measuring cement setting times by needle penetration.
Details safety precautions, warnings against disassembly, modification, or operation in unsuitable environments.
Explains the meaning of caution, danger, and note symbols used in the manual.
Outlines the manufacturer's warranty terms and conditions for the equipment.
Instructs on inspecting the equipment upon delivery for visible condition and completeness.
Describes the packaging and handling precautions for transporting the equipment.
Provides instructions for placing and operating the equipment under specified ambient conditions.
Lists the standard accessories included with the apparatus.
Details how to safely connect the apparatus to the power supply, including electrical tolerances and fuse information.
Details technical specifications, acoustic emission, and penetration patterns of the Vicat apparatus.
Explains how to connect and switch on the apparatus, including initialization and touch screen operation.
Provides step-by-step instructions for installing the USB-RS232 adapter driver on Windows.
Describes the settings mode for parameter adjustment and the monitoring mode for observing tests.
Details parameters that can be set for the touch display, water temperature, airflow, and Vicat device itself.
Explains how to select and change the display language on the apparatus.
Details how to adjust the display brightness using the touch screen controls.
Explains how to adjust the desired heating temperature set point for the water bath.
Details how to set the hysteresis value for the heating control of the water bath.
Instructs on setting the desired cooling temperature set point and its hysteresis value.
Explains how to adjust the correction factor for the water temperature sensor to ensure accuracy.
Graphically illustrates and explains the operation of the heating and cooling processes for water temperature control.
Details parameters for optimizing heat transfer via airflow control, including heat sink temperatures and correction factors.
Explains how to set the upper and lower temperature limits for the heat sinks to control fan speed.
Details setting the run-on temperature for fans and adjusting the correction factor for the airflow sensor.
Describes how to manually stop the heat sink fans before reaching the run-on temperature.
Details parameter settings for the humidity sensor, including slope, zero voltage, and offset.
Explains how to adjust the slope parameter and zero voltage for the humidity sensor using a keypad.
Details how to adjust the offset parameter for the humidity sensor to improve accuracy.
Explains how to select the appropriate cleaner device (for needle or cone) based on the material being tested.
Details how to set the Y and Z coordinates for the cleaner device position and needle immersion depth.
Guides on accurately setting the Y-coordinate for the sample center to ensure correct puncture point distance.
Explains the process of determining the zero level (Z-coordinate) for accurate measurements, especially with different base plates.
Details how to set the penetration time for the needle or cone between 0 and 10 seconds.
Explains how to observe test progress, including measurement count, temperature, penetration depth, and status indicators.
Instructs to install and configure the VicatMPM software on the PC and refers to the software manual.
Provides visual guidance on how to correctly place and fix a sample into the Vicat ring on the measuring station.
Details the procedure for starting a test on the EN device, including water bath preparation and PC software initiation.
Explains how to start tests on the ASTM device in a moisture environment, including cup and frame placement.
Guides on adjusting the rubber buffer to prevent the needle from striking the glass plate.
Details the procedure for replacing worn brushes in the device's cleaning mechanism.
Provides step-by-step instructions for safely removing and replacing the Vicat needle.
Explains how to replace the sealing ring located under the sample plate, usually after about 2 years.
States the revision date of the current operating manual and outlines copyright ownership and usage restrictions.
Provides contact information for obtaining spare parts and technical assistance from the manufacturer.