16
TEXI Catenaccio operation manual
(4). Setting of Scale Rate in Y scale
(5). Setting of Limitation on Max Speed
(6). Setting End
Press to record the set values like pattern number, X/Y scale rate and so on.
Press to reconfirm each set item, but the Sewing LED can’t changes its status.
Press to turn off the Sewing LED, then each set value of item can be changed
When the pattern number is 0 (the default setting), pressing will activate the error “E-10”. At this time, please
press the Reset Key to reconfirm the pattern number.
1.Press , and then the LED of will be
displayed.
2.Press & to display 100 at Data
Display LED.
(The Scale Rate in Y Direction is set as 100%)
The setting exceeding 100% is dangerous
since needle and the cloth presser
interferes with each other and needle
breakage or the like will occur.
1.Press , and then the LED of will
be displayed.
2.Press & to display 400 at Data
Display LED
(The limitation is set as 400 rpm)
1. Press .
2. After the presser goes up, the Sewing LED is on.
At this time the system is in the sewing status.
When the presser is raised, be careful that fingers are not caught in the presser since the presser moves
after having lowered.