25
TEXI Catenaccio operation manual
2) Press to have access to debugging mode, the monitor will show “CP---” as displayed in the following picture:
; ;
3) Press to perform the display output test. This test will check the display module and indicator of each LED in
cycle; the following is the specific procedure:
4) Press again to end the display output test. The monitor will display “CP-1” as shown in the following picture:
.
5) Press & to change the program code of the function test. The function stood by each code is shown in
the following table:
6) Hold to have access to the function test.
7) During the function test, if user presses , the test will be stopped and the system will return to the status of 5);
However, if the continuous mode has been used for once, the test will be unable to be released. For ending the test, the
user can only turn off the power.
Only after the display output test, can the user perform the test on other functions.
11. Debugging Mode
Via this mode, user can perform the operations of maintenance and checking.
1) When the Sewing LED is off, press to call the display of . Then press at
same time. After the ring of buzzer, the system will have access to the debugging mode via the user level setting mode
of memory switch.
(Attention) Not pressing at same time will cause the failure of access to debugging mode.