A40i, A60i
SERVICE Manual 0-5466
5-8
3. Remove the filter element and clean or replace..
NOTE!
If replacing or cleaning just the filter ele-
ment refer to the following illustration for
disassembly.
Filter Element
4. Install the new or cleaned assembly by reversing these procedures.
5. Turn ON the air supply and check for leaks before reinstalling the cover.
Optional Single-Stage Filter Element Replacement
These instructions apply to power supplies where the optional Single-Stage Filter has been installed.
The Power Supply shuts down automatically when the Filter Element becomes completely saturated. The Filter
Element can be removed from its housing, dried, and reused. Allow 24 hours for Element to dry. Refer to Section
6, Parts List, for replacement filter element catalog number.
1. Remove power from power supply.
2. Shut OFF air supply and bleed down system before disassembling Filter to change Filter Element.
3. Disconnect gas supply hose.