A40i, A60i
Manual 0-5466 SERVICE
5-9
4. Turn the Filter Housing Cover counter-clockwise and remove it. The Filter Element is located inside the
Housing.
Art # A-02476
Filter
Element
(Cat. No. 9-7741)
Housing
Cover
Barbed
Fitting
Spring
Assemb
led Filter
O-ring
(Cat.
No. 9-7743)
Optional Single-Stage Filter Element Replacement
5. Remove the Filter Element from the Housing and set Element aside to dry.
6. Wipe inside of housing clean, then insert the replacement Filter Element open side first.
7. Replace Housing on Cover.
8. Reattach gas supply.
NOTE!
If unit leaks between housing and cover,
inspect the O-ring for cuts or other damage.