25
IMPORTANT!
If the pump is removed or has just been replaced, it is necessary to fill it with oil before starting the
machine. If the machine is started without oil in the hydrostat, the supply pump of the hydrostat will
be damaged!
Once the hydrostat is attached to the machine, you mount the hose to the hydrostatic pump. Fill the
suction hose with oil before it is attached to the filter box.
Fill the filter box with oil and mount the filter and put the lid on. Then fill the hydraulic tank. Attach
a suction pump to the test fittings on the right side of the pump.
Start venting the hydrostatic pump with suction through the test fittings. As soon as oil comes out of
the test fittings, you take the suction pump off and attach a manometer. Spin the engine , without
starting it up. When the hydraulic pump creates pressure, the hydrostat is prepared for operation.