7. Applied Operation and Setting of Various Functions
34
1 Set up the RL-SV2S on Point A of the on-grade line using the weight on the tripod.
2 Using the sight at the upper section of the RL-SV2S, adjust the direction on top of the tripod
and roughly align the X+ direction to Point B on the standard axis.
3 Horizontally rotate the laser beam of the RL-SV2S. (X+0%,Y+0%)
4 At Point B adjust the height of the LS-80L installed on a pole, align the standard position of
the LS-80L with the laser beam and fix.
5 Set the RL-SV2S at X+0% and Y-3% grades.
6 Align the RL-SV2S direction on top of the tripod so as to have the laser beam in the on-
grade position of the LS-80L in step
4.
G
Do not change the height of the LS-80L installed on the pole.
If the height of the RL-SV2S is changed, return to step
4 and redo the adjustment.