11. Specifications
60
Protection against water and dust : IP66 (Based on the standard IEC60529)
Operating temperature : –20 °C to +50 °C (–4 °F to +122 °F)
Storable temperature range : –30 °C to +60 °C (–22 °F to +140 °F)
ÌÓ÷áòîéîçäéóðìáù : RL-SV2S height alert warning
(Warning is displayed on the indicator of LS-80L.)
RL-SV2S battery warning
(Warning is displayed on the indicator of LS-80L.)
Dimensions : 177 (L) × 196 (W) × 217 (H) mm [7.0 (L) × 7.7 (W) × 8.5 (H) in]
Laser beam height : 187mm
(Height from the instrument’s bottom surface to the center point of
laser beam)
Weight : 2.5kg (lbs) (Dry battery type: Including dry batteries)
2.7kg (lbs) (Ni-MH battery type: Including BT-74Q)
Tripod screw : 5"/8X11 threads for surveying instrument
RC-60
Operating range (Radius) : 100m or more
Power source : 2×AA size dry cell batteries
Continuous operating time(+20°C): Approx. 3.5 months (depends on the nature of use)
Protection against water and dust : IP66 (Based on the standard IEC60529)
Operating temperature : –20 °C to +50 °C (–4 °F to +122 °F)
Storable temperature range : –30 °C to +60 °C (–22 °F to +140 °F)
Dimensions : 116 (L) × 59 (W) × 31.4 (H) mm [4.6 (L) × 2.3 (W) × 1.2 (H) in]
Weight : 0.2kg (0.4lbs) (Including dry cell batteries)