12. Error Display
63
Transmission error with remote control.
Change both the RL-SV2S and RC-60 to other channel.
If the error persists, check the transmission
environment and reduce wireless LAN and
other similar wireless transmissions as
much as possible.
More than 2 RL-SV2S devices are within the transmission range of the
RC-60, making transmission impossible. Change the channel for both
the RL-SV2S (1) and RC-60 used for the operation to another channel.
Exceeding the adjustment range.
Turn the power of the RL-SV2S OFF, turn ON the power back again
and readjust.
E-05 Turn the power for the instrument off, and then turn it back on.
Error Display Description/Countermeasure