CHAPTER 4– DATA COMMUNICATIONS INTERFACE
32 MultiLoad II/ RCU II Explosion Proof Lite (EXL) Installation Guide - Part # 6070
4.2.3.1 COM2 – RS232 - Host Ticket Printer/Data Logger
A Ticket Printer or Data Logger can be connected to the MultiLoad II/ RCU II via RS232 on COM
2.
The TX and RX are swapped at the MultiLoad II/ RCU II.
Handshake lines MUST be connected or terminated, or a printer error will be reported.
MultiLoad II/ RCU II will monitor CTS, DSR and DCD for active signals.
Figure 4.9 Ticket Printer / Data Logger Connections with Handshake
Figure 4.10 Ticket Printer / Data Logger Connections without Handshake
When Print or Alibi Log is configured to be on COM 2, the CTS handshake line MUST be
connected, or a printer error will occur, preventing loading.
MultiLoad II/