5.Movethesection-valvemanifoldandgaskets
downtoclearthesection-bypassvalveandthen
awayfromthemachine(Figure114).
Note:Ifneeded,loosenthemountinghardware
fortheleftorrightsection-valvemanifoldsas
neededtoprovideclearance.
Note:Retaintheangeclamps,gasketsand
quick-connectpinsforinstallationinInstalling
theAgitation-ManifoldValve(page85).
CleaningtheManifoldValve
1.Positionthevalvestemsothatitisintheclosed
position(Figure115B).
g027562
Figure115
1.Valveopen2.Valveclosed
2.Removethe2end-cap-ttingassembliesfrom
eachendofthemanifoldbody(Figure116and
Figure117).
g028243
Figure116
AgitationValveManifold
1.Stemretainer7.BackseatingO-ring(0.676
x0.07inch)
2.Valvestem8.Valve-seatring
3.Stemport9.Manifoldbody
4.Stem-captureretainer
10.Ballvalve
5.End-captting11.End-cap-ttingassembly
6.End-capsealO-ring
(0.796x0.139inch)
82