AdjustingtheBrakePedal
ServiceInterval:Every200hours
Note:Removethefonthoodtoeasetheadjustment
procedure.
1.Removethecotterpinandclevispinsecuring
themastercylinderyoketothebrake-pedal
pivot(Figure62).
g002417
Figure62
1.Mastercylinderyoke2.Brake-pedalpivot
2.Liftuponthebrakepedal(Figure63)untilit
contactstheframe.
3.Loosenthejamnutssecuringtheyoketothe
mastercylindershaft(Figure63).
4.Adjusttheyokeuntilitsholesalignwiththehole
inthebrake-pedalpivot.
5.Securetheyoketothepedalpivotwiththeclevis
pinandcotterpin.
6.Tightenthejamnutssecuringtheyoketothe
mastercylindershaft.
Note:Thebrakemastercylindermustrelieve
pressurewhenproperlyadjusted.
g036549
Figure63
1.Clutchpedal
3.Acceleratorpedal
2.Brakepedal
52