e-STUDIO163/203 ADJUSTMENT December 2005 © TOSHIBA TEC
3 - 32
[A] Installation of the high-voltage transformer jig
(1) Open the bypass tray, ADU and transfer
cover.
(2) Open the front cover and take off the toner
cartridge.
(3) Disconnect 1 connector. Loosen 2 screws
and pull out the process unit.
Note: Note:
Be careful not to let the connector and the
harness be caught when installing the pro-
cess unit after adjustment.
Fig. 3-15
(4) Install the high-voltage transformer jig and fix
it with 2 screws.
Note: Note:
Be careful not to let the connector and the
harness be caught.
Fig. 3-16
(5) Fix the green cable of the high-voltage trans-
former jig to the frame of the equipment.
Fig. 3-17
ConnectorProcess unit
High-voltage transformer jig
Green cable