December 2005 © TOSHIBA TEC e-STUDIO163/203 ADJUSTMENT
3 - 11
3
3.2.4 Scanner related adjustment
[A] Reproduction ratio adjustment of the primary scanning direction
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON # (Adjustment Mode)
(2) Place a ruler on the original glass (along the direction from the rear to the front of the equipment).
(3) Press [0] and [9] simultaneously to enter the normal mode.
(4) Make a copy at the mode of A3 (LD), 100% and standard drawer of the equipment.
(5) Press [0] and [5] simultaneously to enter the adjustment mode.
(6) Measure the distance A from 10 mm to 270 mm of the copied image of the ruler.
(7) Check if the distance A is within the range of 260±0.5 mm.