December 2005 © TOSHIBA TEC e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 51
2
804-0 Fuser Temperature
control lower
limit
(Envelope)
Center
thermistor
ALL 11
<0-12>
M 0: 130°C 1: 135°C
2: 140°C 3: 145°C
4: 150°C 5: 155°C
6: 160°C 7: 165°C
8: 170°C 9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
804-1 Side ther-
mistor
ALL 11
<0-12>
M 4
805 Charger Main charger bias correc-
tion
(Text/Photo/OHP film)
PRT 98
<0-255>
M Corrects the value of
the main charger bias
adjustment (05-210).
1
806 Charger Main charger bias correc-
tion
(Toner Saving Mode/OHP
film)
PRT 98
<0-255>
M 1
807 Charger Main charger bias correc-
tion
(Text/Photo/OHP film)
PPC 98
<0-255>
M 1
808 Charger Main charger bias correc-
tion
(Text/OHP film)
PPC 98
<0-255>
M 1
809 Charger Main charger bias correc-
tion
(Photo/OHP film)
PPC 98
<0-255>
M 1
814 Charger Main charger
bias correc-
tion
(Text/Photo/
OHP film)
GDI PRT 98
<0-255>
M 1
819 Charger Main charger
bias correc-
tion
(Text/Photo)
GDI PRT 128
<0-255>
M 1
826 Charger Main charger bias correc-
tion
(Toner saving mode)
PRT 128
<0-255>
M 1
830 Transfer Transfer transformer DC
correction (C)
ALL 128
<0-255>
M Corrects the value of
the transfer trans-
former DC output
adjustment (05-221).
1
831 Separa-
tion
Separation transformer DC
correction (C)
ALL 128
<0-255>
M Corrects the value of
the separation trans-
former DC output
adjustment (05-234).
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Proce-
dure
06/04