2
© 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455
SELF-DIAGNOSIS MODES
2 - 201
Notes:
• Sub-code 3 is equivalent to sub-code 7.
• When the value of sub-code 3 is changed, the value of sub-code 7 is also updated and vice
versa.
• When “0” is set at one of sub-codes 0, 3, 6 and 7, the rest of them are automatically updated
to “0”.
Items
PM management
setting <Procedure
4> *Indicated in 8
digits
Date of previous
replacement
<Procedure 2>
Remarks
Photoconductive drum 1150-0 to 8 1151 <Default values of code 1150
(e-STUDIO205L/255/305/355/455)>
Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0/0/0
Sub-code 1: 80,000/100,000/120,000/
125,000/150,000
Sub-code 4: 161,000/161,000/161,000/
135,000/135,000
Drum cleaning blade 1158-0 to 8 1159 <Default values of code 1158
(e-STUDIO205L/255/305/355/455)>
Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0/0/0
Sub-code 1: 80,000/100,000/120,000/
125,000/150,000
Sub-code 4: 161,000/161,000/161,000/
135,000/135,000
Drum separation finger 1172-0 to 8 1173 <Default values of code 1172
(e-STUDIO205L/255/305/355/455)>
Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0/0/0
Sub-code 1: 80,000/100,000/120,000/
125,000/150,000
Sub-code 4: 161,000/161,000/161,000/
135,000/135,000
Charger grid 1174-0 to 8 1175 <Default values of code 1174
(e-STUDIO205L/255/305/355/455)>
Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0/0/0
Sub-code 1: 80,000/100,000/120,000/
125,000/150,000
Sub-code 4: 161,000/161,000/161,000/
135,000/135,000
Charger (Wire) 1182-0 to 8 1183 <Default values of code 1182
(e-STUDIO205L/255/305/355/455)>
Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0/0/0
Sub-code 1: 80,000/100,000/120,000/
125,000/150,000
Sub-code 4: 161,000/161,000/161,000/
135,000/135,000
Ozone filter 1198-0 to 8 1199 <Default values of code 1198
(e-STUDIO205L/255/305/355/455)>
Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0/0/0
Sub-code 1: 240,000/200,000/240,000/
250,000/300,000
Sub-code 4: 483,000/322,000/322,000/
270,000/270,000
Developer material 1200-0 to 8 1201 <Default values of code 1200
(e-STUDIO205L/255/305/355/455)>
Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0/0/0
Sub-code 1: 80,000/100,000/120,000/
125,000/150,000
Sub-code 4: 161,000/161,000/161,000/
135,000/135,000