© 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455
PREVENTIVE MAINTENANCE (PM)
5 - 17
5.7 Preventive Maintenance Checklist
The following is the check items of each unit at preventive maintenance.
Symbols/Values used in the checklist
Notes:
• Perform cleaning and lubricating in the following timing. Lubricate the replacement parts
according to the replacement cycle.
- e-STUDIO205L: every 80,000 sheets
- e-STUDIO255: every 100,000 sheets
- e-STUDIO305: every 120,000 sheets
- e-STUDIO355: every 125,000 sheets
- e-STUDIO455: every 150,000 sheets
• Values under “Replacement” indicate the replacement cycle for the e-STUDIO205L/255/305/
355/455.
• The replacement cycle of the parts in the feeding section equals to the number of sheets fed
from each paper source.
• Be careful not to put oil on the rollers, belts and belt pulleys when lubricating.
Cleaning Lubrication/Coating Replacement Operation check
A: Clean with alcohol
B: Clean with soft pad,
cloth or vacuum
cleaner
L: Launa 40
SI: Silicon oil
W1: White grease (Molykote EM-
30L)
W2: White grease (Molykote HP-
300)
AV: Alvania No.2
FL: Floil (GE-334C)
CG: Conductive grease (KS-660)
Value: Replacement
cycle
R: Replace if
deformed or
damaged
After cleaning or
replacement, confirm