e-STUDIO205L/255/305/355/455 © 2009 TOSHIBA TEC CORPORATION All rights reserved
SELF-DIAGNOSIS MODES
2 - 62
2.7.2 Setting codes
Notes:
• The digit after the hyphen in “Code” of the following table is a sub code.
• In "Board", the SRAM of the board in which the data of each code is stored is indicated. "M"
stands for the LGC board, "SYS", "NIC" and "UTY" stands for the SYS board.
Setting mode (08)
Code
Classific
ation
Items
Functi
on
Default
<Acceptable
value>
Boa
rd
Contents
Proce
dure
200 General Date and time setting ALL -
<13 digits>
- Year/month/date/day/
hour/minute/second
Example:
03 07 0 13 13 27 48
“Day” - “0” is for
“Sunday”. Proceeds
Monday through
Saturday from “1” to
“6”.
5
201 General Destination selection ALL EUR: 0
UC: 1
JPN: 2
<0-2>
M0:EUR
1: UC
2: JPN
1
202 User
interface
Counter installed
externally
ALL 0
<0-4>
M 0: No external counter
1: Coin controller
2: Copy key card
(This value is valid
only when “2” is set
to 08-201.)
3: Key copy counter
4: Key card for OEM1
1
203 General Line adjustment mode ALL 0
<0-1>
M 0: For factory
shipment
1: For line
* Field: “0” must be
selected
1
204 User
interface
Auto-clear timer setting ALL 3
<0-10>
SYS Timer to return the
equipment to the
default settings when
the [START] button is
not pressed after the
function and the mode
are set
0: Not cleared
1 to 10:Set number x 15
sec.
1
205 User
interface
Auto power save mode
timer setting
ALL 4
<0-15>
SYS Timer to automatically
switch to the Auto
power save mode when
the equipment has not
been used
0: Invalid
4: 1min.
5: 2min.
7: 4min.
8: 5min.
9: 7min.
10: 10min.
11: 15min.
12: 20min.
13: 30min.
14: 45min.
15: 60min.
1