e-STUDIO205L/255/305/355/455 © 2009 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
6 - 8
6.2.2 Service call
Error code Classification Contents Troubleshooting
C010 Drive system
related service call
Main motor abnormality: The main motor is not rotating
normally.
P. 6-64
C040 Paper feeding
system related
service call
PFP motor abnormality: The PFP motor is not rotating
normally.
P. 6-65
C130 Upper drawer tray abnormality: The upper drawer tray
motor is not rotating or the upper drawer tray is not
moving normally.
P. 6-65
C140 Lower drawer tray abnormality: The lower drawer tray
motor is not rotating or the lower drawer tray is not
moving normally.
P. 6-65
C150 PFP upper drawer tray abnormality: The PFP upper
drawer tray motor is not rotating or the PFP upper drawer
tray is not moving normally.
P. 6-66
C160 PFP lower drawer tray abnormality: The PFP lower
drawer tray motor is not rotating or the PFP lower drawer
tray is not moving normally.
P. 6-66
C180 LCF tray-up motor abnormality: The LCF tray-up motor is
not rotating or the LCF tray is not moving normally.
P. 6-67
C1A0 LCF end fence motor abnormality: The LCF end fence
motor is not rotating or the LCF end fence is not moving
normally.
P. 6-67
C1B0 LCF transport motor abnormality: The LCF transport
motor is not rotating normally.
P. 6-68
C260 Scanning system
related service call
Peak detection error: Lighting of the exposure lamp
(white reference) is not detected when power is turned
ON.
P. 6-69
C270 Carriage home position sensor not turning OFF within a
specified period of time: The carriage does not shift from
its home position in a specified period of time.
P. 6-69
C280 Carriage home position sensor not turning ON within a
specified period of time: The carriage does not reach to
its home position in a specified period of time.
P. 6-69
C3D0 Process related
service call
EPU board memory overwriting error: The overwriting of
the EPU board memory fails.
P. 6-71
C3D1 EPU board memory new parts detection error: The EPU
board detects the process unit as a new unit when the
equipment is started in the normal mode.
P. 6-71
C3D2 EPU board memory old parts detection error: The EPU
board cannot detect the new process unit when the
equipment is started in the initial detection mode ([7] +
[START]).
P. 6-71
C410 Fuser unit related
service call
Thermistor or heater abnormality at power-ON:
Abnormality of service call the thermistor is detected
when power is turned ON or the temperature of the fuser
roller does not rise in a specified period of time after
power is turned ON.
P. 6-71
C430 Thermistor abnormality after abnormality judgment:
Abnormality of the thermistor is detected after a specified
period of time has passed from power-ON (including
ready state).
P. 6-72
C440 Heater abnormality after abnormality judgment: The
temperature of the fuser roller has exceeded the range of
control or does not even reach the range.
P. 6-72
C450 Thermistor abnormality during printing: Abnormality of the
thermistor is detected during printing.
P. 6-72
C4C0 Fuser unit new/old detection fuse abnormality P. 6-71