5
© 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455
PREVENTIVE MAINTENANCE (PM)
5 - 3
5.2.3 PM display contents
When the counter value exceeds the setting value, the equipment notifies you of when the
maintenance time has come by displaying the message “Time for periodic maintenance ****” on the
control panel LCD. “****” in the message is a 4-digit hexadecimal number code. This number is
allocated in the following manner, therefore the parts needing maintenance can be identified.
PM parts of the process unit (K) : 0008
PM parts of the developer material (K) : 0080
Parts other than the PM parts of the process unit : 0100
If multiple parts have reached the maintenance time, the sum of the corresponding code values listed
above is displayed in hexadecimal numbers.
For example, if the peripheral parts of the process units (K) and developer material (K) reach the
maintenance time, the 4-digit hexadecimal number code will be “0188” in hexadecimal numbers:
0008+0080+0100=0188.