e-STUDIO205L/255/305/355/455 © 2009 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
6 - 124
6.4.5 Blurred image
Fig. 6-5
Defective area Step Check items Prescription
Paper 1 Is the paper in the drawer or LCF
damp?
Change paper. Avoid storing paper in
damp place.
Bedewed scanner 2 Is the scanner bedewed? Clean the scanner.
Drum 3 Is the drum surface wet or dirty? Wipe the drum with a piece of dry
cloth.
* Do not use alcohol or other
organic solvents.
Ozone exhaust 4 Is the exhaust fan operating
properly?
Check the connection of connector.
Replace the ozone exhaust fan.
5 Is the ozone filter stained or
damaged?
Replace the ozone filter.
Feeding direction