EasyManua.ls Logo

Toshiba e-studio205L - Page 482

Toshiba e-studio205L
672 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO205L/255/305/355/455 © 2009 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
6 - 78
[CB11] Standby side tray drive motor abnormality
[CB12] Turning roller drive motor abnormality
[CB20] Delivery motor abnormality
MJ-1101
Is there any mechanical problem when the entrance roller is rotated?
YES Fix the mechanism.
NO
Is the harness between the entrance motor (M1) and the finisher control PC board (CN7)
disconnected or open circuited?
l
YES Reconnect the connector securely.
Replace the harness.
NO
1. Replace the entrance motor (M1).
2. Replace the finisher control PC board.
* You receive a [CB11] error when the [ED16] error occurs three times in succession.
MJ-1101
Is there any mechanical problem when the buffer tray guide is opened/closed while the buffer
roller is lifted up?
YES Fix the mechanism.
NO
Is the harness between the buffer tray guide motor (M3) and the finisher control PC board
(CN18) disconnected or open circuited?
l
YES Reconnect the connector securely.
Replace the harness.
NO
1. Replace the buffer tray guide motor (M3).
2. Replace the finisher control PC board.
MJ-1101
Is there any mechanical problem when the buffer roller is rotated?
YES Fix the drive mechanism.
NO
Is the harness between the buffer roller drive motor (M6) and the finisher control PC board
(CN18) disconnected or open circuited?
l
YES Reconnect the connector securely.
Replace the harness.
NO
1. Replace the buffer roller drive motor (M6).
2. Replace the finisher control PC board.
MJ-1025
Is the delivery belt home position sensor (PI7) working properly?
NO Replace the sensor.
YES