SETTING / ADJUSTMENT
6 - 18
[D] Image position adjustment of the secondary scanning direction
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode)
(2) Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3) [SETTINGS] [USER FUNCTIONS] Select [DRAWER] Select [DRAWER1]
Set the paper size to A3/LD. [OK] Set A3/LD for the paper in upper drawer.
(4) [CANCEL] [CANCEL] Select the upper drawer by pressing [DRAWER]. Press [START]
to make copies.
(5) Measure the distance D from the leading edge of the paper to 10 mm of the copied image of the
ruler.
(6) Check if the distance D is within the range of 10±0.5 mm.
(7) If not, use the following procedure to change values and measure the distance D again.
[SETTINGS] (Key in the code [3031]) [START]
(Key in a value (acceptable values: 0 to 255))
[OK] (Stored in memory)
[SETTINGS] Select the upper drawer by pressing [DRAWER]. Press [START] to make
copies.
* The larger the adjustment value is, the more the image is shifted to the trailing edge (approx.
0.13 mm/step).
Fig.6-12
10 20 30 40
D
Feeding direction
Copied image of the ruler