Setting Mode (08) Codes
05/08 Mode Element Sub element Item Subitem Code
Sub-
code
Details
Default
value
cceptable
value
SRAM Contents
Proce
dure
23LA
23LM/
28LM
23HA/
28H
08 Setting
mode
Process Fuser 2002 - Fuser unit error status
counter
0 0-62 M 0: No error 1: C411 error 2: C412 error 3: C413 error 4:
C414 error 5: C415 error 7: C447 error 9: C449 error 19:
C449 error 21: C449 error 22: C449 error 23: C449 error
24: C447 error 25: C449 error 27: C449 error 45: C449
error 62: C452 error
Than the above: C4B0
1YYY
08 Setting
mode
Process Fuser 2009 - Fuser roller
temperature on
standby (Center
thermistor)
8 0-12 M 0: 140 degrees C 1: 145 degrees C 2: 150 degrees C 3:
155 degrees C 4: 160 degrees C 5: 165 degrees C 6: 170
degrees C 7: 175 degrees C 8: 180 degrees C 9: 185
degrees C 10: 190 degrees C 11: 195 degrees C 12: 200
degrees C
1YYY
08 Setting
mode
Process Fuser 2010 - Fuser roller
temperature during
printing (Center
thermistor/Plain paper)
8 0-14 M 0: 140 degrees C 1: 145 degrees C 2: 150 degrees C 3:
155 degrees C 4: 160 degrees C 5: 165 degrees C 6: 170
degrees C 7: 175 degrees C 8: 180 degrees C 9: 185
degrees C 10: 190 degrees C 11: 195 degrees C 12: 200
degrees C 13: 205 degrees C 14: 210 degrees C
1YYY
08 Setting
mode
Process Fuser Fuser roller
temperature during
printing (Center
thermistor)
2028 Thick paper 2 13 0-14 M 0: 140 degrees C 1: 145 degrees C 2: 150 degrees C 3:
155 degrees C 4: 160 degrees C 5: 165 degrees C 6: 170
degrees C 7: 175 degrees C 8: 180 degrees C 9: 185
degrees C 10: 190 degrees C 11: 195 degrees C 12: 200
degrees C 13: 205 degrees C 14: 210 degrees C
1YYY
08 Setting
mode
Process Fuser 1st printing pre-
running operating
time
2031 Thick paper 2 12 0-15 M 0: Invalid 1: 1sec 2: 2sec 3: 3sec 4 : 4sec 5: 5sec
6: 6sec 7: 7sec 8: 8sec 9: 9sec 10: 10sec 11:
12sec 12: 14sec 13 : 16sec 14: 18sec 15: 20sec
1YYY
08 Setting
mode
Process Fuser 2040 - Drop control when
ready
1 0-2 M 0: Invalid, 1: Valid, 2: Invalid in low temperature 1 Y Y Y
08 Setting
mode
Process Fuser Temperature drop
setting in ready
status (Center
thermistor)
2041 0 The first drop 2 0-10 M Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4YYY
08 Setting
mode
Process Fuser Temperature drop
setting in ready
status (Center
thermistor)
2041 1 The second drop 2 0-10 M Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4YYY
08 Setting
mode
Process Fuser Temperature drop
setting in ready
status (Center
thermistor)
2041 2 The third drop 2 0-10 M Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4YYY
08 Setting
mode
Process Fuser Temperature drop
setting in ready
status (Center
thermistor)
2041 3 The fourth drop 2 0-10 M Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4YYY
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
14-2-29
e-STUDIO2303A/2303AM/2803AM/2309A/2809