HX7+ ASD Installation and Operation Manual 109
RX Speed Frequency #1
Program Frequency Setting  Speed Reference Setpoints RX
This parameter is used to set the gain and bias of the RX input terminal when 
the RX terminal is used as the control input while operating in the Speed 
Control mode.
See RX Speed Reference #1 (F216) for further information on this setting.
This parameter sets RX Speed Frequency #1 and is the frequency that is 
associated with the setting of RX Speed Reference #1 while operating in the 
Speed Control mode.
Direct Access Number —  F217
Parameter Type — Numerical
Factory Default — 0.0
Changeable During Run — Ye s
Minimum — -Max. Freq. (F011)
Maximum — Max. Freq. (F011)
Units — Hz
RX Speed Reference #2
Program Frequency Setting  Speed Reference Setpoints RX
This parameter is used to set the gain and bias of the RX input terminal when 
the RX terminal is used as the control input while operating in the Speed 
Control mode or the Torque Control mode.
See RX Speed Reference #1 for further information on this setting when used 
for Speed control or Torque control.
This parameter sets the RX input level that is associated with RX Speed 
Frequency #2 while operating in the Speed control mode or is associated with 
the RX Torque Reference Setpoint #2 while operating in the Torque control 
mode.
Direct Access Number —  F218
Parameter Type — Numerical
Factory Default — 100.00
Changeable During Run — Ye s
Minimum — -100.0
Maximum — 100.0
Units — %
RX Speed Frequency #2
Program Frequency Setting  Speed Reference Setpoints RX
This parameter is used to set the gain and bias of the RX input terminal when 
the RX terminal is used as the control input while operating in the Speed 
Control mode.
See RX Speed Reference #1 for further information on this setting when used 
for Speed control.
This parameter sets RX Speed Frequency #2 and is the frequency that is 
associated with the setting of RX Speed Reference #2 while operating in the 
Speed Control mode.
Direct Access Number —  F219
Parameter Type — Numerical
Factory Default — 80.00
Changeable During Run — Ye s
Minimum — -Max. Freq. (F011)
Maximum — Max. Freq. (F011)
Units — Hz
RX Torque Reference Setpoint #1
Program Torque Setting  Setpoints RX
This parameter is used to set the gain and bias of the RX input terminal when 
the RX terminal is used as the control input while operating in the Torque 
Control mode.
This is accomplished by establishing an associated V/f output pattern for a 
given RX input level.
See RX Speed Reference #1 for further information on this setting.
This parameter sets RX Torque Reference Setpoint #1 and is the output torque 
value that is associated with the setting of RX Speed Reference #1 while 
operating in the Torque control mode.
Direct Access Number —  F220
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Ye s
Minimum — -250.00
Maximum — 250.00
Units — %
F217 F220