Peripheral Installation
8-10
Strata CTX I&M September 2002
External Page with BIOU Interface
Up to two BIOU interfaces can be installed for connecting external page equipment. Each BIOU can
provide up to four unique page zones for a total of eight page zones maximum per system. The BIOU
interfaces can be installed in the main cabinets and/or any remote cabinet. Each BIOU provides a
600ohm, non-amplified page output and an 8 ohm, 3-watt amplified page output. Only one type of
page output, amplified or non-amplified, can selected per BIOU in a given installation. The BIOU also
provides a control relay which can be used to mute external BGM when the external page circuit is
active (see Figures 8-8~8-12 for connection diagrams).
Figure 8-9 Single Zone Page Options
A separate external BGM source can be connected to a building’s external Page speakers using the
BIOU interface. This enables the BGM sent over the external page speakers to be different from the
BGM sent to telephone speakers (see Figures 8-10) for separate BGM over external Page connections).
Figure 8-10 Separate BGM Over External Page
SW600 (Select SPO or SP1)
System
Back Plane
5605
BIOU (1 or 2)
SPTO 38, BK-GN
SPRO 13, GN-BK
Jacketed
Twisted Pair
CW1308 0.5
66 Block Wiring
Page, BGM
or Night Ringing
switched in by
System Processor
HESB
or
External
Amplifier
and Speaker
(8ohm minimum)
HESB
or
External
Speaker
600
Transformer
SPT1 50, V-S
SPR1 25, S-V
SPO
SP1
Level Control
3 Watt Amplifier
SP
BGM Mute Relay
2
1
Night Ring
and Page
from KSU
Backplane
600
SPT (38) BK-GN
GN-BK
Input 1
Output
External
Paging Amp
M
BGM
Music
Source
Mute 2
Input 2
B
BIOU (1 on 2)
SPR (13)
MDF
5601

Table of Contents