2-6
Strata CTX I&M September 2002
Strata CTX100 Installation
Note
The figure below show the position of the screws. Back covers should be removed before the
Base and Expansion cabinets are attached to each other.
Figure 2-4 Base and Expansion Cabinet Back Covers
Step 3: Check the Base/Expansion Power Supply Jumper Plug
The APSU112F power supply is used in both CTX100 cabinets.
➤
Check that the “BASE/EXP.” jumper plug is connected to the proper power supply connector as
shown in Figure 2-14. The power supply has two connectors: one is labelled “BASE” and the other
“EXP.”
♦
If the power supply is mounted in the CTX100 Base Cabinet, the “BASE/EXP.” jumper plug
must be plugged into the “BASE” connector.
♦
If the power supply is mounted in the CTX100 Expansion cabinet, the jumper plug must be
plugged into the “EXP.” connector.
Step 4: Mount the Base Cabinet
1. Make sure the location of the Base Cabinet meets the minimum clearance requirements specified
in Figure 2-1 on Page 2-3.
Note
The Base Cabinet AC power cord is 1.37m (4ft 5”) long.
2. Attach a 1.27cm (1/2”) thick plywood back board to the wall where the CTX100 will be installed.
Secure the back board to the wall with screws attached to the wall studs, shown in Figure 2-5.
3. Place the Base Cabinet back cover at the desired location on the back board using a level and mark
the location of the four screw holes (there is one on each corner).
4. Drill holes on these marks.
WARNING! To prevent electrical shock, make sure the power supply is not plugged into
the AC outlet.
Remove 1 screw
EXPANSION BASE
5933