2 Troubleshooting Procedures   2.3 Power Supply Troubleshooting 
2-12 [CONFIDENTIAL]    Satellite Pro S300, TECRA A10/S10/P10  Maintenance Manual (960-684) 
  Main Battery 
Error code  Meaning 
22h  Main battery discharge current is over 0.5A. 
23h  Main battery charge current is over 4.3A. 
24h  The compensation value of [0A] is not within the limits from design data (± 
400mA). 
25h  Main battery charge current is over 0.3A when the charging is off. 
 
  2nd Battery 
Error code  Meaning 
32h  Second battery discharge current is over 0.5A. 
33h  Second battery charge current is over 2.7A. 
34h  The compensation value of [0A] is not within the limits from design data (± 
400mA) 
35h  Second battery charge current is over 0.3A  
 
  S3V output 
Error code  Meaning 
40h  S3V voltage is over 3.47V. 
45h  S3Vvoltage is under 3.14V. 
46h  S3V voltage is under 3.14V or less when the computer is booting up. 
 
  E5V output 
Error code  Meaning 
50h  E5V voltage is over 6.00V. 
51h  E5V voltage is under 4.50V when the computer is powered on. 
52h  E5V voltage is under 4.50V when the computer is booting up. 
54h  E5V voltage is under 4.50V when EV power is maintained.