4.26 Fluorescent Lamp 4 Replacement Procedure
TECRA M3 Maintenance Manual (960-507) 4-107
Attaching the tapes and insulation sheet
1. Attach the PCB insulation sheet (one point).
2. Install the lamp clip.
3. Attach the tape for fixing the lamp clip (one point).
4. Attach the tape for fixing the FL cable (one point).
CAUTION: When attaching tape and insulation sheet, be careful not to damage the TAB
and lamp cable connections.
Figure 4-79 Replacing TMD fluorescent lamp (XGA) (11)
Stick the tape, making the line as a guide
Fixing tape for lamp
Fixing tape for FL
Lamp clip
Stick the tape, making the
The tape must not be overlaid with the
Install the clip into the level