Register Function / Title Bank Mask Adjustment Range Multiplier
60 “OUT” CONTACTS HOLD
TIME
0 / 1 00FF 0001 0064 (1 100) 1
61 LOW SPEED SIGNAL
OUTPUT FREQ
0 / 1 FFFF 0 Fmax 0.01
62 ACC/DEC COMPLETE
DETECT BAND
0 / 1 FFFF 0 Fmax 0.01
63 SPEED REACH MAXIMUM
FREQUENCY
0 / 1 FFFF 0 Fmax 0.01
64 SPEED REACH MINIMUM
FREQUENCY
0 / 1 FFFF 0 Fmax 0.01
65 COMMERCIAL
POWER/INV SWITCHING
OUTPUT
0 / 1 00C0 0000: OFF (0)
0040: Auto switch on trip (1)
0080: At COMMERCIAL PWR/INV
SWITCH FREQ (2)
00C0: Both (1) and (2) (3)
66 2, 3
COMMERCIAL
POWER/INV
SWITCH FREQ
0 / 1 FFFF 0 Fmax 0.01
67 “FP” OUTPUT
TERMINAL PULSE
FREQUENCY
0 / 1 0003 0000: 48f (0)
0001: 96f (1)
0002: 360f (2)
68 RR INPUT SPECIAL
FUNCTION SELECT
0 / 1 00E0 0000: Standard (0)
0040: Fmax (1)
0080: TACC/TDEC mult. (2)
00C0: VB mult. Factor (3)
0020: CL mult. Factor (4)