3. Extended parameters
[1] Frequency signal Sensorless vector/PG feedback control (:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector
control
PM
control
V/f Reference
 0100 Low-speed signal output frequency 0.0~ Hz 0.1/0.01 0.0 Enabled / 6. 1. 1
 0101 Speed reach setting frequency 0.0~ Hz 0.1/0.01 0.0 Enabled / 6. 1. 2
 0102 Speed reach detection band 0.0~ Hz 0.1/0.01 2.5 Enabled / 6. 1. 2
[2] Input signal selection Sensorless vector/PG feedback control (:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector
control
PM
control
V/f Reference
 0105
Priority when forward/reverse run
commands are entered simultaneously
0:Reverse run
1:Stop
1/1 1 Disabled / 6. 2. 1
 0106 Input terminal priority selection
0:Disabled
1:Enabled
1/1 0 Disabled / 6. 2. 2
 0108 Analog VI/II voltage/current switching
0:Voltage input
1:Current input
1/1 0 Disabled / 6. 2. 3
 0109
Analog AI2 (optional circuit board)
voltage/current switching
0:Voltage input
1:Current input
1/1 0 Disabled / 6. 2. 3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-PS1 and is the answer not in the manual?

Toshiba TOSVERT VF-PS1 Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-PS1
CategoryPower Supply
LanguageEnglish

Related product manuals