EasyManua.ls Logo

Toshiba VF-PS1 - Page 278

Toshiba VF-PS1
307 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
K-36
E6581386
11
[Input terminal function setting (1/2)] Sensorless vector/vector with sensor (: valid, -: invalid)
Positive
logic
Negative
logic
Function
Vector
control
PM control V/f = = Reference
0 1 No function is assigned /●● --
2 3 F: Forward run command /●● -
4 5 R: Reverse run command /●● -
6 7 ST: Standby /●● *1 -
8 9 RES: Reset /●● *2 -
10 11 S1: Preset speed 1 /●● -
12 13 S2: Preset speed 2 /●● -
14 15 S3: Preset speed 3 /●● -
16 17 S4: Preset speed 4 /●● -
18 19 Jog run /●●
20 21 Emergency stop /●● *2 -
22 23 DC braking /●●
24 25 Acceleration/deceleration switching /●● -
28 29 V/f switching signal /●● -
36 37 PID control OFF selection /●● -
46 47 External thermal error / -
48 49 Communication priority cancel / -
50 51
Holding of HD operation (stop of three-wire
operation)
/ -
52 53 PID differentiation/integration reset / -
54 55 PID forward/reverse switching / -
56 57 Forced continuous operation / -
58 59 Specified speed operation / -
64 65 My function RUN signal / -
66 67 Auto-tuning signal / -
74 75 Integrating wattmeter display clear / -
76 77 Trace back trigger signal / -
86 87 Binary data write / -
88 89 Up/Down frequency (up)*3 / -
90 91 Up/Down frequency (down)*3 / -
92 93 Up/Down frequency (clear) / -
98 99 Forward/reverse selection / -
7.2.1
*1: Valid any time
*2: Independent of , and all command are valid.
*3: The deceleration/deceleration time depends on the / setting, unless switching between acceleration and deceleration is performed.

Table of Contents