5.2 Wiring
5.2.1 Conductor Cross Section
Power Supply (Batt. Plus, GND): AWG20 (0.62 mm²)
Signals:
AWG22 (0.38 mm²)
The conductors must be approved for aircraft use. Recommended Quality:
MIL-Spec 22759/34, (Spec 55) 20AWG / 22AWG
Crimped D-Sub connector is always preferred against soldered connectors. Original TQ harness comply
with common aviation wiring standards. Consult your approved aviation shop for installation details.
5.2.2 Wiring Scheme
Figure 48: Wiring