01/26/2023 TR-ELA-BA-DGB-0026-04 Page 37 of 52
4 Installation
4.1 Basic rules
Power and signal cables must be laid separately. During installation, observe the
applicable national safety and installation regulations for data and power cables.
Separation respectively differentiation of the measuring system from possible
interfering transmitters.
Observe the manufacturer's instructions for the installation of converters and for
shielding power cables between frequency converter and motor.
To ensure safe and fault-free operation, the following standards and guidelines
are to be observed:
- IO-Link Design Guide, PNO Order-No.: 10.912
- IEC 60947-5-2, Low-voltage switchgear and controlgear
- EMC directive
Upon completion of installation, a visual inspection with report should be carried
out.