EasyManua.ls Logo

TR-Electronic LMRS-34 - Index 0 X0010 - 0 X0018: Identification Parameters; Parameterization

TR-Electronic LMRS-34
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameterization
TR-Electronic GmbH 2017, All Rights Reserved Printed in the Federal Republic of Germany
Page 42 of 52 TR-ELA-BA-DGB-0026-04 01/26/2023
7 Parameterization
Parameter data are exchanged acyclic and only on request of the IO-link master. The
parameter data are addressed by means of a so-called Index and Subindex.
This mechanism is performed as an acknowledged service. The IO-Link master
specifies in its Request the parameter Index, the access method (Read/Write)
and if necessary the value. The IO-Link device performs the write or read access and
answers the request with a Response. In the case of an error (error code = 0x80) an
error message gives information about the cause of error, see chapter ISDU error
types on page 50.
By means of subindex 0x00 the complete index is addressed, by means of the sub-
indices 0x01…0xFF the individual parameters are addressed, if these are available.
7.1 Index 0x0010 - 0x0018: Identification parameters
The identification parameters contain device data, which the IO-Link master requires
in the start-up phase, in order to be able to identify the connected device.
These device data can be read out by means of their index and subindex = 0x00 from
the device or can be written into the device if write access is permissible.
The objects with index 0x0040 and 0x0041 are optional and were added by the
manufacturer.
Index
Object Name
Description
Value (StringT)
Access
0x0010
Vendor Name
Vendor name
TR-Electronic GmbH
ro
0x0011
Vendor Text
Vendor text
www.tr-electronic.com
ro
0x0012
Product Name
Product name
device specific
ro
0x0013
Product ID
Product-ID
device specific
ro
0x0014
Product Text
Product text
Magnetostrictive
linear encoder
ro
0x0015
Serial-Number
Serial number
device specific
ro
0x0016
Hardware
Revision
Hardware version
device specific
ro
0x0017
Firmware
Revision
Firmware version
device specific
ro
0x0040
Order number
Article number
device specific
ro
0x0041
Measuring
length of
encoder
Measuring length
in mm
device specific
ro
To describe the user specific application, function and location each object supports a
text string with a size of 32 bytes:
Index
Object Name
Value (StringT)
Type
Access
0x0018
Application Specific Tag
***
StringT32
r/w
0x0019
Function Tag (UTF-8)
***
StringT32
r/w
0x001A
Location Tag (UTF-8)
***
StringT32
r/w

Table of Contents

Other manuals for TR-Electronic LMRS-34