Printed in the Federal Republic of Germany TR-Electronic GmbH 2017, All Rights Reserved
01/26/2023 TR-ELA-BA-DGB-0026-04 Page 43 of 52
7.2 Device parameters
7.2.1 Index 0x0042: Temperature
The parameter Temperature contains the current measuring system temperature in
[°C] and is output as a two's complement value with preceding sign.
7.2.2 Index 0x0043: Count direction
The parameter Count direction defines whether rising or falling position values
are output when the magnet moves towards the end of the rod.
Position decreasing to rod end
Position increasing to rod end
7.2.3 Index 0x0044: Resolution
The parameter Resolution defines the length of a measuring step.
The resolution set here and the measuring length stored in the measuring system
(index 0x0041, Measuring length of encoder) results in the total number of steps over
the entire measuring range of the measuring system.
Measuring length in steps =