7.2 Device parameters
7.2.1 Index 0x0042: Temperature
The parameter Temperature contains the current measuring system temperature in
[°C] and is output as a two's complement value with preceding sign.
Index
Subindex
Name
Length
Type
Access
0x0042
0
Temperature
8 Bit
IntegerT
ro
7.2.2 Index 0x0043: Count direction
The parameter Count direction defines whether rising or falling position values
are output when the magnet moves towards the end of the rod.
Index
Subindex
Name
Length
Type
Access
0x0043
0
Count direction
8 Bit
BooleanT
r/w
Value
Assignment
Description
Default
0x01: TRUE
to the
connector
Position decreasing to rod end
0x00: FALSE
from the
connector
Position increasing to rod end
X
7.2.3 Index 0x0044: Resolution
The parameter Resolution defines the length of a measuring step.
Index
Subindex
Name
Length
Type
Access
0x0044
0
Resolution
16 Bit
UIntegerT
r/w
Value
Assignment
Default
0x0005
5 µm (only LMP-30)
device
specific
0x000A
10 µm
0x0014
20 µm
0x0032
50 µm
0x0064
100 µm
The resolution set here and the measuring length stored in the measuring system
(index 0x0041, Measuring length of encoder) results in the total number of steps over
the entire measuring range of the measuring system.
Measuring length in steps =
Measuring length [mm]
Resolution [mm]