8 RTHD-SVX01D-EN
General Information
Digit 31 -Thermal Insulation
X No insulation
Q Factory insulation cold parts
Digit 32 -Sound Attenuator
X No insulation
A Standard attenuator
Digit 33 -Control, Label, and Literature
C Spanish
E English
FFrench
Digit 34 -Safety Devices
X Standard
Digit 35 -Shipping Charge
A Full Factory Charge (R134a)
B Nitrogen
Digit 36 -Shipping Package
A No skid (standard)
B Shrink Wrap
CSkid
D Skid + Shrink Wrap
J Special
Digit 37 -Flow Switch
X Without
A Evap (NEMA-1)
B Evap & Cond (NEMA-1)
C Evap (Vapor/NEMA -4)
D Evap & Cond (Vapor/NEMA -4)
Digit 38 -Factory Performance Test
X Without
C Witness test
D Performance test w/report
S Special
Digit 39 -Starter type
Y Wye-delta closed transition
starter
A Solid State starter
Digit 40, 41, 42
Design RLA (for starter)
*** Selection RLA
Digit 43
Power line connection type
A Terminal block connection for
incoming line(s)
B Mechanical disconnect switch
D Circuit breaker
F High interrupt circuit breaker
H Ground fault circuit breaker
J Ground fault high interrupt circuit
breaker
Digit 44 -Enclosure type
F
NEMA 1 - MRLA207
G NEMA 1 - MRLA277
H
NEMA 1 - MRLA300
J NEMA 1 - MRLA364
K
NEMA 1 - MRLA397
L NEMA 1 - MRLA476
M NEMA 1 - MRLA500
N NEMA 1 - MRLA598
P NEMA 1 - MRLA779
Digit 45 -Under/over voltage
protection
X No under/over voltage
protection
U Under/over voltage protection
Digit 46 -Unit operator interface
A Dyna-View/English
B Dyna-View/French
C Dyna-View/Italian
D Dyna-View/Spanish
E Dyna-View/German
F Dyna-View/Dutch
G Dyna-View/Trad.Chinese
H Dyna-View/Simp.Chinese
J Dyna-View/Japanese
K Dyna-View/Portugese(Brazil)
L Dyna-View/Korean
M Dyna-View/Thai
Digit 47
Remote Interfaces (digital comm)
X No remote digital comm
4 Tracer Comm 4 Interface
5 Tracer Comm 5 LCI-C (LonTalk )
Digit 48
External Chilled Water & Current Limit
Setpoint
X None
4 4-20 mA input
2 2-10 Vdc input
Digit 49
External Base Loading
X None
4 4-20 mA input
2 2-10 Vdc input
Digit 50 -Icemaking
X None
A Icemaking with relay
B Icemaking without relay
Digit 51 -Programmable Relays
X None
R Programmable Relay
Digit 52
Chilled water reset
X No Sensor (return water CHW
reset standard)
T Chilled water reset - outdoor air
temp
Digit 53 - Control Outputs
X None
V Condenser reg. Valve out & %
RLA out
P Condenser Pressure (%HPC) &
% RLA out
D Chiller Delta P & %RLA out
Digit 54 -Refrigerant Monitor Input
X None
A 100 ppm / 4-20 maA
B 1000 ppm / 4-20 mA
C 100 ppm / 2-10 Vdc
D 1000 ppm / 2-10 Vdc