SP3000
Machine overview
BA 8034_2.4_EN (12/2016) 47 / 87
5.2.3 Compressed air display
Display of the compressed air pressure.
By pressing the SET-button the output values can be switched between bar or psi.
The arrow buttons have no functionality.
5.2.4 Compressed air regulator
By turning the compressed air regulator the pressure can be adjusted.
If the pressure of the compressed air is set too high, it can cause damage
to the machine.
- The supplied pressure of the extern connected compressed air must
not exceed 10 bar.
- The maximum compressed air pressure during operation must not
exceed 6 bar.
5.2.5 Key switch
Turning the key switch counterclockwise powers off the motor, laser source and electric
system.
Through the key switch, operation by non-authorized personnel can be prevented.
5.2.6 Emergency stop button
When pressing an emergency stop button, the electric circuit immediately shuts off. The laser beam is
interrupted, and all movements are stopped.
Do not use the emergency stop button for the standard switch off procedure.
5.2.6.1 Emergency stop acknowledgement
1. Turn the emergency stop button
counterclockwise to unlock it.
2. Reboot the laser device to acknowledge the
laser fault.