7.2 Operating environment
7.2.1 Temperature and humidity
Operating temperature:
15 °C to 25 °C (59 °F to 77 °F)
Air humidity:
40% 70% (non-condensing)
7.2.2 Subsoil conditions
Conditions:
- Planarity ±5 mm (±0.1969 inch)
- Solid, firm and vibration-free soil
- Easy-care and clean floor
- Bearing capacity of the subsoil ≥1000kg/m
2
(10KN/m
2
)
- Machine point load 500kg/m² (5KN/m
2
)
- No special substrate preparation required
7.2.3 Environmental conditions
Conditions:
- Provide sufficient illumination at the workplace
- Ensure a dust-free environment (II° according to IEC60947-1)
- Shielding from EMC
- Freedom of interfering electrical installations, hoses and pipe lines
- Power supply free of fluctuations
7.3 Setup and installation
The setup has to be carried out by Trotec technicians only.