RECALL FUNCTION
The Recall function allows the operator to review the last density and
moisture readings.
To execute the Recall function, press 〈SHIFT〉 and 〈RECALL〉. If the
gauge is in Soil mode, the display will be:
If the gauge is in Asphalt mode, the display will be:
DEPTH FUNCTION
The Depth function allows the operator to select one of two depth modes:
manual or automatic. In the Manual mode, the gauge prompts the operator
to manually input the source rod depth using the keypad. In the Automatic
mode, the gauge automatically reads the depth strip on the index rod, and
then determines the source depth. To set the Depth mode, press
〈SHIFT〉
and
〈DEPTH〉.
MANUAL MODE
If the Depth mode is set to Automatic, the gauge display is:
To set the Depth mode to Manual, press 〈1〉 for:
DD=xxxxx
PCF
WD=xxxxx
PCF
M=xxxxx %M=xxxxx
M=xxxxx %M=xxxxx
%VOIDS=xxxxx%
1-
Select
MANUAL
2-
C
al
i
br
a
te
(CE to exit)
MANUAL