DISABLE A SPECIAL CALIBRATION
To disable a previously enabled special calibration, press 〈2〉 from the
SPEC CALIB. menu. The display will be:
The gauge will return to the READY display.
PERFORM A SPECIAL CALIBRATION (RECALIBRATION)
Before performing a special calibration, the following steps must be taken:
1. The sample area must be prepared for testing.
2. Gauge readings must be taken on each area.
3. A wet density measurement using an alternative method must be
performed.
To perform a new special calibration, prepare a test site and position the
gauge. Position the rod at the correct depth and press
〈3〉 from the SPEC
CALIB. menu. The display will be:
Press 〈START/ENTER〉 after input of the rod depth. The display is:
C
AL
IB
R
AT
I
ON
ENABLED!
(
En
te
r
0
fo
r
BS
)
xxinches
(Press ENTER)
D
ep
th
:
x
in
ch
es
Ti
me
:
x
mi
n.
Press START