Appendix A–6
NOTE
Use only a light grade (ISO VG 32, SAE 10) hydraulic
oil to fill the hydraulic reservoir.
Hydraulic power unit – Examine all hoses and fittings for
leaks.
Hydraulic hoses and braided sleeve – Examine the hydraulic
hoses and their braided sleeves for wear. If the sleeve is
worn through and the rubber hydraulic hose is worn, replace
the hose and sleeve.
Open the chamber door and examine each hydraulic hose for
wear. If the rubber cover is worn, replace the hose.
EVERY 500 HOURS OF OPERATION OR ONCE A
YEAR
Remove the right-side service panel. Locate the hydraulic filter
(see Figure A–1). Verify that the bypass indicator on the top of
the filter housing is green. If the bypass indicator is red, the
filter element must be changed. Contact your Troxler
representative for more information.
Figure A–1. Hydraulic Filter Bypass Indicator
ENSURE
BYPASS INDICATOR
IS GREEN