46
B. Bline Mode
Press the and buttons to scroll the cursor to the sensor type. Press the
button to enter the black-mark sensor calibration mode.
B-1 Automatic
When enter the [Automatic] option, you will see following message and printer will
feed the black mark label to calibrate the sensor sensitivity automatically. When
calibration process is completed, the LCD screen will return to the previous menu.
B-2 Manual
In case Automatic sensor calibration cannot apply to the media, please use
“Manual” function to calibrate the bline sensor manually.
When enter [Manual] option, you will see following message. Please complete there
steps
Paper Len.
00151 dot
1. Press the button to move the
cursor from left digit to right digit, and press
the button to set the value from 0 to
9 and the dot/ mm/ inch. Press the
button to set the paper length into
the printer.
Bline Size
0024 dot
2. Press the button to move the
cursor from left digit to right digit, and press
the button to set the value from 0 to
9 and the dot/ mm/ inch. Press the
button to set the bline size into the
printer.
Calibration 2/4
Gap Mode
>
Bline Mode
Cont. Mode
Bline Mode 1/4
>
Automatic
Manual
Pre-Printed
Bline Mode
Automatic
Bline Mode 2/4
Automatic
>
Manual
Pre-Printed

Other manuals for TSC ME240

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC ME240 and is the answer not in the manual?

TSC ME240 Specifications

General IconGeneral
Resolution203 dpi / 300 dpi
Operating Temperature5°C to 40°C (41°F to 104°F)
Print MethodThermal Transfer & Direct Thermal
InterfaceUSB
Power SupplyAC 100-240V, 50/60Hz
Humidity20% to 85% RH (non-condensing)

Related product manuals