49
C. Cont. Mode
Press the and buttons to scroll the cursor to the sensor type. Press the
button to enter the black-mark sensor calibration mode.
C-1 Automatic
When enter the [Automatic] option, you will see following message and printer will
calibrate the sensor sensitivity automatically. When calibration process is completed,
the LCD screen will return to the previous menu.
C-2 Manual
In case Automatic sensor calibration cannot apply to the media, please use
“Manual” function to calibrate the sensor manually.
When enter [Manual] option, you will see following message. Please complete there
steps
Cont. Mode
Remove Label
Intensity x
Ref. Level xxx
1. Remove the continuous label. Press
the button to set the value
into the printer.
Cont. Mode
Scan Paper
Intensity x
Ref. Level xxx
2. Then, put the continuous label under
the media sensor. Press the
button to set the value into
the printer.
Calibration 3/4
Bline Mode
>
Cont. Mode
Exit
Cont. Mode 1/3
>
Automatic
Manual
Exit
Cont. Mode
Automatic
Cont. Mode 2/3
Automatic
>
Manual
Exit

Other manuals for TSC ME240

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC ME240 and is the answer not in the manual?

TSC ME240 Specifications

General IconGeneral
Resolution203 dpi / 300 dpi
Operating Temperature5°C to 40°C (41°F to 104°F)
Print MethodThermal Transfer & Direct Thermal
InterfaceUSB
Power SupplyAC 100-240V, 50/60Hz
Humidity20% to 85% RH (non-condensing)

Related product manuals