Parameterizing and Configuring
IO-Link functions for acyclic communication
122
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
Content Size Format Comment
IOL7 VENDOR_ID 2 byte Unsigned 16
DEVICE_ID 4 byte Unsigned 32
FUNCTION_ID 2 byte Unsigned 16 Value: 0
SERIAL_NUMBER 16 byte String
IOL7 VENDOR_ID 2 byte Unsigned 16
DEVICE_ID 4 byte Unsigned 32
FUNCTION_ID 2 byte Unsigned 16 Value: 0
SERIAL_NUMBER 16 byte String
Subindex 65: IO-Link Events
The object reads IO-Link Event diagnostics.
Entity_Port IO-Link sub index Read/write Length
0 65 Read 255 byte
NOTE
Only ”appears” (coming diagnostics) and ”Single Shot Events” are shown, as long as
they are pending.
Structure of the read data:
n Byte 0 contains 2 bit per IO-Link port which show, if the process data of the connected
device are valid or not.
n Byte 0 is followed by 4 byte per Diagnostic Event which clearly assign and specify the dia-
gnostic message. A maximum of 14 Events per IO-Link port are shown.
Byte no. Bit no. Description
7 6 5 4 3 2 1 0
0 x PD_Valid Input Port 1
x PD_Valid Output Port 1
x PD_Valid Input Port 2
x PD_Valid Output Port 2
x PD_Valid Input Port 3
x PD_Valid Output Port 3
x PD_Valid Input Port 4
x PD_Valid Output Port 4
1 x PD_Valid Input Port 5
x PD_Valid Output Port 5
x PD_Valid Input Port 6
x PD_Valid Output Port 6
x PD_Valid Input Port 7
x PD_Valid Output Port 7
x PD_Valid Input Port 8
x PD_Valid Output Port 8
2 Qualifier Defines the type of the event (Warning, Noti-
fication, Single Shot Event, etc.) in accordance
with IO-Link specification „IO-Link Interface
and System“.