COURIER HIGH SPEED MODEMS
THE AUDIO MONITOR
The
modem's
speaker
enables
you
to
monitor
the
dial-connect
process. There
are
several
ways
to
make
use
of this feature.
After the
Courier
dials a
number,
it
waits
60
seconds
for a high-
pitched
answer
tone
from
the
other
modem,
immediately
fol-
lowed
by
data
signals, called a carrier. These signals
must
occur
before a
data
link
is established.
At
the default
Xl
setting, if
someone
answers
the
phone,
or
if
the
line is
busy,
the
modem
sends
the
message
NO
CARRIER to
your
screen after
60
seconds.
If
you
listen to the speaker,
you
can
respond
immediately
instead
of
waiting
for the
modem
to
time
out.
For example, if
you
hear
someone
answering
the
call,
you
can
pick
up
the
phone,
if
it's
attached
to
the
modem,
and
talk to
the
person.
Or
you
can cancel the call
by
pressing
any
key
on
the
keyboard. In
the
same
way,
you
can
cancel a call
when
you
hear
a
busy
signal.
You can also
hear
if
dialing is
proceeding
too quickly for the
system.
Terminate
the
call (press
any
key)
and
retype
the
Dial
command,
but
insert
a
comma(,)
or
a
couple
of
slashes(/),
to
have
the
modem
pause
during
the
dialing
process.
SPEAKER CONTROL
(Mn)
This
command
disables
the
speaker
entirely
or
sets
the
speaker
to
monitor
different
segments
of
the dial-connect sequence.
MO
This setting disables
the
speaker
entirely so
that
you
don't
hear
the
modem
go
off hook, dial, etc.
Ml
The
speaker
is
ON
until
Carrier
Detect. Default. You
can
monitor
call
progress
until
the
Courier
detects
the
remote
modem's
carrier signals,
or
until
the
60-second
timeout
and
result
code
display.
At
Carrier
Detect,
the
modem
disconnects
the
speaker
and
data
transmission
sounds
are
suppressed.
M2
The
speaker
is
ON
continuously,
including
during
data
transmission.
M3
The
speaker
doesn't
go
ON
until
after the last digit is
dialed,
then
goes OFF
at
Carrier
Detect.