&Yn
COURIER HIGH SPEED MODEMS
&X2
Modem's
Receiver clock is
the
source;
valid
only
in
V.32
bis
mode
or
for 2400/1200-bps connections
in
HST
mode.
Break handling. Destructive Breaks clear
the
buffer;
expedited
Breaks
are
sent
immediately
to
the
remote
system.
Under
data
compression, destructive Breaks cause
both
modems
to
reset
their
compression
tables.
&
YO
Destructive,
don't
send
Break.
&Yl Destructive,
expedited
(Default).
&Y2
Nondestructive,
expedited.
&Y3
Nondestructive,
unexpedited;
modem
sends
Break in
sequence
with
data
received from DTE.
&Zn=s Write
the
following Dial
string
(s)
to NVRAM
at
position
n
(n = 0-3).
&Zn?
Display
the
phone
number
stored
in
NVRAM
at
position
n
(n = 0-3).
&ZC=s Write the following
command
string
(s)
to NVRAM.
&ZC? Display
the
stored
command
string.
PERCENT
COMMAND
SET
%Rn
Rack Controller
Unit
(RCU) access. For
use
with
USRobotics
Total Control
Modem
Management
Systems.
%RO
Normal
operations, RCU access
disabled
(Default).
%R1
RCU access enabled.
% T Touch-Tone Recognition
mode
enabled.
Remote Access Commands
The following
commands
are
valid
only
during
remote
access
sessions,
which
are
described
in
Remote Access in
Appendix
E.
o/oBn
Configure the Courier's serial
port
rate.
%BO
110 bps.
%Bl 300 bps.
%B2
600 bps.
continued