vacon • 74 User interfaces
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
5.3.5.10 Keypad
Table 39. I/O and Hardware menu, Keypad parameters
Code Parameter Min Max Unit Default ID Description
P5.7.1 Timeout time 0 60 min 0
Time after which the display
returns to page defined with
parameter P5.7.2.
0 = Not used
P5.7.2 Default page 0 4 0
The page the keypad shows when
the drive is powered on or when
the time defined with P5.7.1 has
expired. If the value is set to 0 the
page last visited is shown.
0 = None
1 = Enter menu index
2 = Main menu
3 = Control page
4 = Multimonitor
P5.7.3 Menu index
Set menu index for desired page
and activate with parameter P5.7.2
= 1.
P5.7.4
Contrast
*
*. Only available with graphical keypad
30 70 % 50
Set contrast of the display
(30...70%).
P5.7.5 Backlight time 0 60 min 5
Set the time until the back light of
the display turns off (0...60 min). If
set to 0 s, back light is always on.