parameter descriptions vacon
113
9
3.13 M
OTOR
POTENTIOMETER
RAMP
3.14 M
OTOR
POTENTIOMETER
RESET
P3.13 is the speed variation ramp when motor potentiometer reference is in-
creased or decreased.
P3.14 tells under which circumstances the potentiometers reference should
be reset and start over from 0 Hz.
0 = No Reset
1 = Reset if stopped
2 = Reset if powered down
P5.12 and P5.13 sets which digital inputs increase and decrease the motor po-
tentiometers reference.
time
x
y
y/x =
P Motor potentiometer ramp
I/O Motor potentiometer up
I/O Motor potentiometer down
Frequency
Reference
P Min Frequency
P Max Frequency
Figure 9.8: The change of motor potentiometers reference